DV Series Viscometer

DV Series Viscometer delivers reliable viscosity measurement with strong stability, easy operation, and wide application for lab and industrial use.
Comprehensive Display Information:

Monitor critical data in real-time, including Dynamic viscosity, Temperature, Measurement time, Shear rate, Shear stress, Torque%, Speed, Spindle.

Front-Facing Bubble Level:

Ensure your instrument is perfectly leveled with the conveniently located front-facing bubble level, improving accuracy.

High Accuracy and Repeatability:

Achieve precise results with an accuracy of ±1.0% of range and repeatability of ±0.3%, ensuring consistent and reliable data.

Specifications

Model LVDV-1 RVDV-1 HADV-1 HBDV-1 LVDV-2 RVDV-2 HADV-2 HBDV-2
Display High-Resolution LCD Display
Measurement Range (cP) 1*-2M 100**-13M 200**-26M 800**-104M 1*-6M 100**-40M 200**-80M 800**-320M
Speed (rpm/min) 0.3, 0.5, 0.6, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 15, 16, 18, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100 0.1, 0.3, 0.5, 0.6, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 15, 16, 18, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200
Accuracy ±1% (Newtonian fluid FS)
Repeatability ±0.3%
PC Software No No No No Yes Yes Yes Yes
Temperature Probe No No No No Yes Yes Yes Yes
Spindle L1, L2, L3, L4 R2, R3, R4, R5, R6, R7 L1, L2, L3, L4 R2, R3, R4, R5, R6, R7
Sample Volume (ml) 300-400 500 300-400 500
Display Information Dynamic viscosity, Temperature, Time, Shear rate, Shear stress, Torque%, Speed, Spindle
Stop Mode Manual/Automatic (timed measurement)
Dimensions 300×300×450 mm (L×W×H)
Net Weight 5 kg
Power Supply Input AC100V-230V, Output DC12V 2A
Power 40W
Optional Accessories • PT100 temperature sensor • ULR ultra-low viscosity adapter • SSR small amount of sample adapter • constant temperature bath • printer • DV upper computer software • viscosity standard solution.

Viscosity unit conversion: 1Pa.s=1000mPa.s, 1P=100mPa.s, 1mPa.s=1cP, M=1,000,000, FS=Full Scale
* If the measured viscosity is lower than 15cP, ULR Adapter is required.
** To measure the viscosity from the lower limit to this point, R1 spindle is required.

Effectively Manage Quality Issues

Learn how we address rework and returns to maintain the highest quality standards and ensure customer satisfaction.
Reasons for Rework
Reasons for Replacement

Client Feedback & Reviews

Discover what our clients have to say about their experience with our products and services.

* Your information is very secure. We will not share your information with any third patries.

KEEP IN TOUCH

Request a Quote

Your query matters to us. We’ll connect shortly, and your details always remain secure.
Email Us

info@martests.com

Let's Talk

Phone : +86 182 1706 8101

Head Office

No. 552, Dongzhou Road, Dongjing Town, Songjiang District, Shanghai, China.

* Your information is very secure. We will not share your information with any third patries.